Bunched copper, PVC insulated and sheathed, 1100 V

PVC Flexible Cables

Flexible multicore cable with class 5 bunched copper conductors, PVC insulated and PVC sheathed. For power and lighting circuits indoors and outdoors, on single or three phase systems up to 1100 V.

IS 694 1100 V AC / 1500 V DC to earth 2, 3, 4 and 5 core
  • Class 5 bunched copper conductor to IS 8130 — high flexibility
  • PVC Type D insulation and Type ST3 sheath to IS 5831
  • Core identification to IS 694:2010
  • Flammability tested to IEC 60332-1-2
  • HR PVC insulation (85 °C) available on request
  • FR and FRLSH sheath compounds available
Construction IS 694
Conductor
Bunched copper to IS 8130, class 5
Insulation
PVC Type D to IS 5831
Sheath
PVC Type ST3 to IS 5831
Test voltage
3000 V AC at 20 ± 5 °C
Temperature
Fixed installation −15 °C to +70 °C
Bending radius
6 × overall diameter fixed, 8 × occasional

Schedules

Dimensions, weight and ratings

Dimensions in millimetres, weights in kg/km, currents in amperes. Tables scroll sideways on narrow screens.

Two core — dimensions and weight

15 rows
Size (n × mm²)Insulation thicknessOverall dia.Weight (kg/km)
2 × 0.50.66.0252
2 × 0.750.66.4362
2 × 10.66.7871
2 × 1.50.67.3287
2 × 2.50.78.83131
2 × 40.810.32188
2 × 60.811.67252
2 × 10114.76412
2 × 16117.04583
2 × 251.220.37861
2 × 351.223.151154
2 × 501.427.751657
2 × 701.431.512219
2 × 951.636.282974
2 × 1201.639.563633

Three core — dimensions and weight

19 rows
Size (n × mm²)Insulation thicknessOverall dia.Weight (kg/km)
3 × 0.50.66.3660
3 × 0.750.66.8073
3 × 10.67.1885
3 × 1.50.67.76105
3 × 2.50.79.38160
3 × 40.810.98231
3 × 60.812.63321
3 × 10115.93524
3 × 16118.18741
3 × 251.221.971113
3 × 351.224.751486
3 × 501.429.652133
3 × 701.433.682874
3 × 951.638.803862
3 × 1201.642.324738
3 × 1501.846.695797
3 × 185252.037241
3 × 2402.258.339210
3 × 3002.464.8811518

Four core — dimensions and weight

19 rows
Size (n × mm²)Insulation thicknessOverall dia.Weight (kg/km)
4 × 0.50.66.9173
4 × 0.750.67.4188
4 × 10.67.83103
4 × 1.50.68.68134
4 × 2.50.710.26198
4 × 40.812.07289
4 × 60.813.86402
4 × 10117.51658
4 × 16120.03937
4 × 251.224.461426
4 × 351.227.541906
4 × 501.432.742715
4 × 701.437.203668
4 × 951.642.894935
4 × 1201.646.816066
4 × 1501.851.697428
4 × 185257.629285
4 × 2402.264.6311820
4 × 3002.471.9214794

Five core — dimensions and weight

6 rows
Size (n × mm²)Insulation thicknessOverall dia.Weight (kg/km)
5 × 0.50.67.5073
5 × 0.750.68.0690
5 × 10.68.72110
5 × 1.50.69.45139
5 × 2.50.711.22206
5 × 40.813.43309

Current carrying capacity and conductor resistance

19 rows
Size (mm²)B — 2 coreB — 3/4 coreC — 2 coreC — 3/4 coreE — 2 coreE — 3/4 coreMax. DC res. (Ω/km)
0.543.643.639
0.75767626
111101211141219.5
1.514121614181513.3
2.51917222025217.98
42522302633284.95
63128383442363.3
104338524758501.91
165751706378661.21
2576689581100850.78
3594841161001251060.554
501121001421221521290.386
701421221801551961650.272
951701512181882382010.206
1201961742522192772330.161
1502181902902523202690.129
1852482153312883663070.106
2402902513893404343630.0801
3003322864473925004190.0641

Reference method B: enclosed in conduit or trunking. C: clipped direct. E: free air or perforated tray. Ambient air 40 °C, conductor 70 °C. Derived from BS 7671 Table 4D2A.

De-rating factor — ambient temperature

1 rows
Ambient35 °C40 °C45 °C50 °C55 °C60 °C65 °C
Factor1.081.000.910.820.700.570.40

Dimensions and weights are approximate and subject to manufacturing tolerance. Current ratings assume the stated installation conditions — apply the de-rating factors for anything else, and confirm against the mill certificate before ordering.