BS EN 124 Ductile iron · A15 to F900

Manhole covers and engineering castings for the GCC.

Royal Trading supplies ductile iron access covers, drainage gratings and purpose-made castings to contractors, consultants and utilities — designed to your drawings, cast to specification and delivered to site.

Product families
11
Catalogued references
192
Load classes
A15–F900
Standards
BS EN 124

What we do

Design. Source. Supply.

Most casting problems on site start on the drawing. We work the detail up front — clear opening, seating, seal type, load class — so what arrives fits the chamber that was actually built.

01

Design

Working from your drawings or ours, we detail the casting — clear opening, frame depth, seating, badging and load class — and issue approval drawings before anything is tooled.

02

Source

We place work with foundries qualified to cast in ductile iron, grey iron and specialist alloys, from half a kilogram up to a tonne, with pattern making handled in house.

03

Supply

Consolidated delivery to site across the GCC, with material certificates, load test reports and installation support against each consignment.

The range

11 families, 192 catalogued references

Every family below carries a full dimensional schedule — clear opening, over base, frame depth, seal type and load class. Pick a family to see the tables.

Schematic

Square and circular sealed access covers

Solid Top Covers

Ductile iron solid top covers and frames for sewer, storm water and utility chambers. Available single or double seal, …

B125 C250 D400 Specs
Schematic

Two-piece covers for large clear openings

Double Triangular & Semi Circular

Two-piece triangular and semi-circular covers give a large clear opening while keeping each leaf within safe manual han…

D400 Specs
Continuous channel grating run

Gullies, channels, catch basins and surface boxes

Drainage Gratings

A full surface-water range: top entry and side entry gullies, continuous channel gratings and bearer bars, catch basin …

C250 D400 Specs
Multi-leaf telecom cable chamber cover in a street

Multi-leaf cable chamber covers and frames

Telecom Covers

Long-span cable chamber covers built from two, four or six leaves in a single frame. Available solid top or recessed fo…

D400 Specs
Recessed cover filled with the surrounding block paving

Filled covers that disappear into the finished surface

Recessed Covers

Recessed covers are filled on site with the surrounding paving, screed or asphalt so the chamber reads as part of the f…

B125 D400 Specs
Circular solid top cover installed at a port

Round covers and frames including 860 mm heavy duty

Circular Covers

Round covers seat evenly under load and cannot fall into the shaft. The range runs from Ø750 access covers up to an Ø86…

B125 C250 D400 Specs
Multi-part water-tight covers

Bolted watertight boxes and multi-leaf spans

Pull Box & Multipart Covers

Bolt-down pull box covers with a neoprene seal for watertight cable and utility chambers, plus multi-part solid top cov…

B125 C250 D400 F900 Specs
Schematic

Hinged access that opens to 100° and stays put

Hinge Covers & Gratings

Stainless steel hinge pin assemblies let a single operator open the cover safely and leave it standing at 100°, with a …

B125 D400 Specs
Continuous trench cover run along a quay

Continuous slide-out runs for pumping stations

Trench Covers

Continuous recessed trench cover systems for pumping stations and service ducts. Covers slide out along the run rather …

D400 F900 Specs
Stainless steel clad frame on site

Ductile iron core, stainless steel clad edge

Steel Cladding Recessed Covers

Recessed covers with a stainless steel clad frame and cover edge for architectural interiors, lobbies and wet areas whe…

D400 Specs
Concrete infill pumping station cover set into a road

Multispan pumping station covers filled on site

Concrete Infill Covers

Slide-out pumping station covers filled with C45 concrete on site so the finished surface reads continuous. Frames are …

D400 F900 Specs

In the field

Installed, and carrying traffic

Covers, gratings and trench systems of the types we supply, in service across roads, ports and utility networks.

BS EN 124

Specify by where it sits, not by what it weighs

The load class follows the installed location. Get that right and the rest of the specification falls into place.

A15
15 kN · Group 1
Pedestrian and pedal cyclist areas

Areas that can only be used by pedestrians and pedal cyclists.

B125
125 kN · Group 2
Footways, car parks, light vehicles

Suitable for car parks, footways and areas accessible to normal light vehicle traffic.

C250
250 kN · Group 3
Kerbside channels

For kerbside channel areas of roads, extending up to 500 mm into the carriageway.

D400
400 kN · Group 4
Carriageways and hard shoulders

Suitable for hard shoulders, roads carrying heavy traffic, pedestrian areas and all types of road vehicle.

E600
600 kN · Group 5
Docks and aircraft pavements

For areas of fast moving and especially heavy traffic, such as docks and aircraft pavements.

F900
900 kN · Group 6
Very high wheel loads

For areas involving particularly high wheel loads, such as aircraft pavements.

Materials & standards in full

Where it goes

Built for infrastructure

Airports

Apron, taxiway and landside castings to E600 and F900.

Ports & terminals

Heavy duty covers for container yards and quay services.

Sewerage networks

Sealed and double-seal covers for gravity and pressure mains.

Storm water

Gullies, channel gratings, catch basins and curb inlets.

Roads & highways

D400 carriageway covers, surface boxes and kerb drainage.

Telecom & power

Multi-leaf cable chamber covers and pull boxes.

Rail networks

Trackside service ducts and trench cover runs.

Pumping stations

Slide-out multispan concrete infill cover systems.

Enquiries

Tell us what the chamber needs

Product codes, clear openings, or just the load class and where it sits. We come back with a priced offer and a lead time — usually within one working day.

  • Clear opening and over-base dimensions, or the product code
  • Load class, or where the cover sits in the finished surface
  • Seal type — single, double, or GRP sealing plate
  • Badging, lettering and paint requirements
  • Quantities, project name and delivery location

Fields marked * are required. We use your details only to answer this enquiry.

Next step

Send us the schedule.

Drawings, a bill of quantities, or just the chamber sizes and load class — we will come back with a priced offer and a lead time.